CJX2 Standard Series

CJX2 Standard Series

The CJX2 Standard Series is a family of low-voltage AC contactors used for frequent switching of electric motors, lighting, heating, and other electrical loads in industrial and commercial installations. These contactors are designed for AC control circuits and are suitable for use in motor starter combinations, automation panels, HVAC systems, and general switching applications. The series complies with IEC 60947-4-1 / GB14048.4 standards, offering reliable mechanical endurance, low coil power consumption, and a range of contact ratings and auxiliary options.


Technical Specifications

Model Identification

Specification Details
Series CJX2 Standard
Product Type AC Contactor
Standards Compliance IEC 60947-4-1 / GB14048.4
Mounting Panel / DIN rail (depending on accessory kit)

Electrical Ratings

Parameter Specification
Control Voltage (Coil) AC 24 V / 36 V / 110 V / 220 V / 380 V AC (50/60 Hz)
Main Circuit Rating AC-3 / AC-4 load categories
Rated Operational Voltage (Ue) Up to 690 V AC
Rated Insulation Voltage (Ui) 1000 V AC
Rated Impulse Withstand Voltage (Uimp) 6 kV
Frequency 50/60 Hz
Number of Poles 1, 2, 3, 4 poles (depending on variant)

Contact & Load Ratings

Model Poles AC-3 Rated Current AC-4 Rated Current Application
CJX2-9 3 9 A 4 A Small motors / loads
CJX2-12 3 12 A 6 A Small to medium loads
CJX2-18 3 18 A 9 A Medium loads
CJX2-25 3 25 A 12.5 A Larger loads
CJX2-32 3 32 A 16 A Medium high loads
CJX2-40 3 40 A 20 A Heavier loads
CJX2-50 3 50 A 25 A High load motors

Contact ratings may vary slightly by manufacturer and specific catalog; always verify with exact model sheet.


Coil & Control Data

Parameter Specification
Coil Voltage Options AC 24 V, 36 V, 48 V, 110 V, 220 V, 380 V
Coil Power Consumption ≤ 10 VA (varies with coil voltage)
Coil Operating Frequency 50/60 Hz
Control Type AC coil with contact feedback option
Mechanical Interlock Available for multi-contactor assemblies

Auxiliary Contacts & Add-Ons

Accessory Function
Auxiliary Contact Blocks (1NO/1NC) Status signaling / logic input
Mechanical Interlock Kit Prevents simultaneous closing of multiple contactors
Surge Suppression (RC Snubber) Reduces coil switching spikes
Timer Modules Delay ON/OFF control
Thermal Overload Relay (paired with CJX2) Motor overload protection

Mechanical & Environmental

Parameter Specification
Operating Temperature Range −5 °C … +40 °C
Humidity ≤ 90 % (non-condensing)
Mechanical Life ≥ 10⁷ operations
Electrical Life (AC-3) ≥ 10⁵ operations
Mounting Panel or Clip-on DIN rail adapter (model dependent)

Typical Pole / Load Table

CJX2 Model Poles AC-3 Load (A) AC-4 Load (A) Typical Use
CJX2-9 3P 9 A 4 A Small motor / lighting
CJX2-12 3P 12 A 6 A Small motor / heater
CJX2-18 3P 18 A 9 A Medium motor
CJX2-25 3P 25 A 12.5 A Larger motor
CJX2-32 3P 32 A 16 A Medium high loads
CJX2-40 3P 40 A 20 A Higher load motors
CJX2-50 3P 50 A 25 A Heavy duty motor

Typical Applications

  • Motor starter panels

  • HVAC and pump systems

  • Conveyor and automation lines

  • Lighting and resistive load switching

  • Control panels requiring frequent switching